Produktinformation
Tri-Colour and 7-Colour Bargraphs – NA3, NA5 and NA6 series.
NA3-F
> 4 seven-segment LED display
> digit height: 7mm
> indication range: -1999 to 9999
> multicolour bargraph of 82mm length
> 45 segments in the 3-colour version
> 25 segments in the 7-colour version
> 96mm x 24mm
NA3B
> multicolour bargraph as above
> without LED display
> without front panel buttons
> 96mm x 24mm
NA3-D
> 4 seven-segment LED display
> digit height: 14mm
> indication range: -1999 to 9999
> 96mm x 24mm
NA5
> 4 seven-segment LED display
> digit height: 7mm
> indication range: -1999 to 9999
> multicolour bargraph
> 88mm lenght
> 55 segments (3-colour)
> 29 segments (7-colour)
> 144x48mm
NA6
> 2×4 seven-segment LED display
> digit height: 7mm
> indication range: -1999 to 9999
> multicolour bargraph
> 88mm lenght
> 48 segments (3-colour)
> 27 segments (7-colour)
> 144x48mm
Applikationer
- Independent scaling of bargraph and digital display
- Wide choice of formats
- Accepts many common industrial signals
- Inter-channel Maths functions x + – / in NA6
Kopplingar

Mått NA series
| NA3 | NA5, NA6 | |
| Dimensions: | 96x25x125mm (with terminals) | 48x144x100mm (with terminals) |
| Panel cutout: | 22.2(+0.5) x 92(+0.5)mm | 44(+0.5) x 137.5(+0.5)mm |
Analogue outputs (optional):
Galvanically isolated, resolution 0.025% of the range.
Current scalable: 0/4 to 20mA, load resistance <500 Ohms
Voltage scalable: 0 to 10V, load resistance >500 Ohms
Output response time 100mS
Output error 0.2% of the range
Thermal stability (0.1% of the range/10K)
Relay outputs (optional) See over for solid-state types:
2 relays (NA3) or 4 relays (NA5, NA6)
Volt-free contacts – maximal load:250 Va.c., 150Vdc, 5A
Programmable alarm limits
Three types of alarms
Hysteresis defined by means of the lower and upper limit
Signalling of alarm operation on the bargraph
Solid state alarms:
2 (NA3) or 8 (NA5, NA6) outputs open collector:
NPN transistor max. load 25mA, 24V DC
Communication outputs:
Interface RS-485
Transmission protocol MODBUS,
ASCII 8N1, 7E1, 7O1,
RTU 8N2, 8E1, 8O1, 8N1
Baud rate 2400, 4800 or 9600
Response time to the query frame 300ms
Excitation voltage in NA5 and NA6 only:
24 V d.c., max. load 20mA
Memory parameters:
Mter memory (recording):
NA3 750 samples
NA5, NA6 750 samples (channel 1 or 2)
or 375 samples (channel 1)
+375 samples (channel 2)
Minimal recording interval 1s
Basic error:
NA3 0.2% +/-1 digit
NA5, NA6 0.1% +/- 1 digit
Additional error from ambient temperature changes:
NA3 0.1% of range/10°C
NA5, NA6 0.05% of the range/10°C
Averaging time:
min 200mS
min 500mS (temp. ranges)
Rated operation conditions:
Supply voltage depending on version ordered 95…230…253V a.c./d.c. or 20…24…40V a.c./d.c.
Supply frequency 40 to 440Hz
Ambient temperature -10 to +55°C
Storage temperature -25 to +85°C
Relative humidity < 95% (non-condensing)
Warmup time 10 minutes
Sustained input overload:
Thermocouples, resistance thermometers 100%
Voltage, current and resistance measurement 110%
Short duration overload (3s):
Inputs of temperature sensors 30V
Voltage input > 2.5V 10 times nominal voltage (< 1000V)
Current input: 10 times nominal current
Bargraph resolution:
programmable
Bargraph accuracy:
+/- 0.5 segment
Sealing:
The trong housing:
NA3 IP 40
NA5, NA6 IP 50
From terminal side IP 20
Dimensions:
NA3 96x25x125mm (with terminals)
NA5, NA6 48x144x100mm (with terminals)
Cut-out dimensions in the panel:
NA3 22.2(+0.5) x 92(+0.5)mm
NA5, NA6 44(+0.5) x 137.5(+0.5)mm
Weight:
< 0.4kg
Power consumption:
NA3 < 8VA
NA5, NA6 < 12VA
Resistance against supply interruption:
According EN 6100-6-2
Electromagnetic compatibility:
Immunity EN 61000-6-2
Emission EN 61000-6-4
Safety requirements according EN 61010-1:
Installation category III
Pollution level 2
Working voltage in relation to ground 500V a.c. max
NA3 specifications
| Inputs: | NA3 |
| Pt100 Pt500 Pt1000 RTD excitation current Max cable ohms | -200 to +850°C -200 to +850°C -200 to +850°C <170uA <20 Ohm/wire |
| J (Fe-CuNi) K (NiCr-NiAI) N (NiCrSi-NiSi) E (NiCr-CuNi) R (PtRh13-Pt) S (PtRh10-Pt) T (Cu-CuNi) | -30 to +1100°C -50 to +1370°C -100 to +1300°C -200 to +850°C -0 to +1760°C -0 to +1760°C -50 to +400°C |
| Resistance measurement | 0-400 Ohms 0-4000 Ohms |
| DC Voltage measurement | 60mV, 3V, 10V, 200V, 600V |
| DC Current measureement | 5mA, 20mA, 2A, 5A |
NA5 & NA6 specifications
| Model LEL-NA5 | Model LEL-NA6 | |
| Numeric display | 55 segments in 3 colours 29 segments in 7 colour | 48 segments in 3 colours 29 segments in 7 colour |
| Inputs | Single Channel RTD PT100, PT500, PT1000 TC types J,K,N,E,R,S,T Resistance 0-400 or 0-4000 Ohm Voltage 0-60mV, 0-3V, 0-10V, 0-200V, 0-600V Current 0-5mA, 0-20mA, 0-2A, 0-5A | Dual Channel RTD PT100, PT500, PT1000 TC types J,K,N,E,R,S,T Resistance 0-400 or 0-4000 Ohm Voltage 0-60mV, 0-3V, 0-10V, 0-200V, 0-600V Current 0-5mA, 0-20mA, 0-2A, 0-5A |
| Output options | 4-20mA or 0-10V 0 or 4 relays 0 or 8 open collector NPN RS485 Modbus | 4-20mA or 0-10V 0 or 4 relays 0 or 8 open collector NPN RS485 Modbus |
| Power | 95-253VAC or 20-40VDC | 95-253VAC or 20-40VDC |