Stordisplayer, Produktionsdisplayer & Panelmetrar
Telefon: +46 (0) 8 445 75 40

INT2-S

INT2-S

Produktinformation

The INT2-S is a low cost yet highly precise, stable, flexible and easy to use 1/8 DIN Serial data input slave display, and our top seller, for both display-only and display + output applications. It is Ideal for remote weighing applications and to repeat the reading on another display.

Interesting fact:
The INT2 is the latest release of this well established display, which was first sold 12 years ago. The fact that it is still a popular seller after all these years is proof that it is ‘right’ for the job. We designed it, we build it, we know it inside out, so you can count on us for first class support.
Now it can also be mounted inside a panel on DIN rail, as a high-performance signal conditioner, transmitter and alarm module. The front panel buttons can be locked, and there is an optional plain front panel with no buttons, which can be put in place of the standard front, after calibration. If you need to be able to read the display in a reflection, for example in a heads-up display system, you can switch it to display a mirrored image.

Plus

You can now order this display with digits up to 400mm high! Exactly the same well-proven software and hardware, but with digits of 57mm, 102mm, 150mm, 200mm, 300mm or 400mm high. Ideal for large factories, or anywhere where you need to see your important measurements from far away, inside or outside. The large version is known as the Fusion family, sealed IP65 all round. See here.

If you need to be able to read the display in a reflection, for example in a heads-up display system, you can switch it to display a mirrored image.

Applikationer

  • Remote weight display
  • Sharing measurements with other operators.
  • Batch totalizing – can add numeric data strings together
  • Serial to analog converter
  • Serial to serial converter – complex to simple format
  • Serial data compared to preset values to create alarms


Blockdiagram

INT2-S Block

Mått

INT2-S Dimensions

INT2-S specifications

Input connectionsAvailable as UL and cUL listed on request.

Open Type, Process Control Equipment, listing number 39CP, File E317722

Produced to IPC 610 Class 2 Standard

UL ISO9001:2008 QA CERT.
Input SignalDetachable plug-in screw terminals
Input SignalAccepts RS232 or RS485 input - please specify which you need.

Modes
ASCII: Displays and ASCII character within the limitations of a 7 segment display.
Quant: Displays only numeric ASCII values.
Qa.Tot: Quantity totaliser. Can be used to accumulate weight values, for example after each batch. Uses a contact closure to trigger addition.

Adjustable parameters
Baud rate: 300 to 115200
Data format: 701, 7e1,7n2,801,8e1,8n1,8n2
Termination character: Hex 00 to FF
Reject Characters: counted from termination char.
Addressing00 (wildcard) to F7
Digits6 digits, 14mm high. Legible up to 7 metres away. 10 readings per second. Variable brightness from front panel.
Digit colourRed - standard. Green - optional
Front panel controlsConfiguration, Tare, Reset, Max/Min, Alarms
Power100-240 VAC std, 11-30VDC option. 10VA Power burden, max.
AccuracyNo error, direct copy of input data.
Analogue outputOptional plug-in 16 bit module
Linearity +/- 0.02% of range

0-20/4-20mA into 0 to 500 Ohms
Resolution 0.4uA
0-10V into loads >600 Ohms
Resolution 0.2mV
-10 to+10V into loads >600 Ohms
Resolution 0.4mV

Accuracy 0.1% of range
Stability 50ppm/C

Fully isolated from input and power
Fully scalable with digital precision

Special features
Forward and reverse action possible
Can be set to operate from nett or gross value.
Alarm outputOptional plug-in relay SPST modules
2 Alarms rated 5A 250VAC, SPST
4 Alarms rated 2A 250VAC, SPST
Selectable normally open or normally closed

Optional plug-in relay SPDT modules
2 Alarms rated 5A 250VAC, SPDT

Optional plug-in solid state modules
2 Alarms rated 50V 100mA DC.

Adjustable hysteresis
In-flight compensation facility.
Energise or de-energise on trip

Special features
Adjustable timers to set energise and de-energise delays. Can also be set to pulse for applications needing less than 100% duty cycle.
In-band and out-of-band alarm function.
Manual and automatic in-flight compensation.
Can be set to operate from nett or gross value.
Serial data outputOptional plug-in modules.
RS232
RS485 Addressable
On demand or continuous output.

Special features
Can include time and date with RTC option fitted.
Can be set to operate from nett or gross value.
Logic inputs3 logic inputs, individually configurable for Hold, Reset, Tare, Peak/valley, Nett/Gross, Memory Address

Normally open, NPN or contact closure input to activate.

5V open circuit, 1mA switched current.
Real time clock optionAccuracy better than 2 minutes per year. Allows date and time to be included in serial data, for example for printing time-stamped records.
Automatic summer/winter time correction for Europe and USA

Battery backup to maintain timing whilst switched off. Type = CR1620 3V Lithium
EnvironmentalStorage -20 to +70C
Operating 0 to 50C
Non condensing.
Optional IP67 cover SPC4
ConnectorsDetachable screw terminals
Bezel size96mm wide x 48mm high. 13mm forward.
Panel cutout92mm wide x 45mm high. +1mm, -0mm
Depth behind panel125mm including connectors + cable.
SealingIP65 standard, IP67 with optional SPC4 cover

 